<LOGO>
FM Transmitter Measurement Report
Created: 2025-08-22 10-14-10
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 55 dBuV Classic
Pilot RDS Phase Difference
6.8 kHz 3.0 kHz 87 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 63 kHz 17501 0,0057
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,7 dBr 2,29 dBr 4,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Cecilia Bartoli (mezzo), Orchestra L "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 63 kHz MIN: 10 kHz % above 76 kHz: 0,0057 Acquired: 2025/08/22 10.13.06 Total samples: 17501 Equivalent time: 0:14:35 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 4,0 dBr MIN: 0,7 dBr AVE: 2,29 dBr % above 12,2 dBr: 0,0 Last value: 1,1 dBr (2025/08/22 10.13.06) 10.00 10.02 10.04 10.06 10.08 10.10 10.12 0 2 4 Pm [dBr]